11-22
Integration Volume
Does the LCD turn OFF on both M1 modular telephone sets that correspond to the Octel
200/300 port being called?
YES
NO
f.
Repeat step 2 for all ports and links until all are tested.
3. PBX FUNCTIONAL TEST (For new install)
This test verifies that each Octel 200/300 port extension can initiate a transfer by doing a
hookswitch flash and a transfer code (or just a hookswitch flash), before entering an extension
number. Also, verify that you can reconnect to the caller when the extension called is not
answered or busy.
a.
Connect telephone B to the modular adapter position associated with port 1 of the Octel
200/300.
b. From telephone A, call the extension number associated with telephone B.
c.
Answer telephone B and perform a hookswitch flash.
d. Does the PBX provide stutter or solid dial tone after the hookswitch flash?
IF NEITHER '
YES
either tone
e.
After several ringbacks have occurred (less than the PBX's configured number of ringbacks
before RNA forwarding), perform a hookswitch flash and reconnect code, if required, to
reconnect to telephone A. Use the code specified in System Parameter 13.
f.
Did telephone C stop ringing? Did you get reconnected to telephone A, which was on hold?
YES
NO
.
4. PBX BUSY FORWARD TEST
This test verifies that a call to a busy extension forwards to the Octel 200/300 hunt group
a.
Connect telephone B to the modular adapter position associated with port 1 of the Octel
200/300.
b. Make telephone C busy by taking it off-hook.
Octel 200/300
S.4.1
Continue the procedure until all ports are tested.
'
Determine the cause and correct the problem before continuing.
'
Stop and correct the problem before continuing.
Enter the extension number associated with telephone C.
'
Connect telephone B to the next Octel 200/300 port extension and
'
continue until all extensions for the Octel 200/300 ports have been
tested.
Determine the cause and correct the problem before continuing.
'
The extension number connected to telephone C should start with the same first digit as
those configured in the USER Table.
.