Avaya Octel 200 Installation And Maintenance Manual page 887

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

15.5 DPNSS TROUBLESHOOTING AND MAINTENANCE
The following troubleshooting and maintenance information is for the DPNSS integration. Refer to the
Installation and Maintenance volume, DTIC chapter, for troubleshooting information specific to the
DTIC.
DPNSS Status
For troubleshooting, you might need to review the status of the DTIC DPNSS state. Three status
commands give information about the status of the trunk and port:
STATUS CARD gives the status of the card used for DTC17-DPNSS.
-
STATUS DCHAN displays the current state of the installed DTIC ports. The port state is shown for
-
each layer, with the first two lines showing the real ports and the third and fourth line showing the
virtual ports.
LIST STATS gives trunk statistics.
-
Use the CONNECT command to logs onto the DTIC. At the @ prompt, enter
CONN x
where x is the slot number for the DPNSS DTIC.
@conn 4
Connecting to DTC17−DPNSS in slot 4
DPNSS>
To exit from DPNSS card status, at the DPNSS> prompt, enter
EXIT
Enter
You are disconnected from the card and returned to the @ prompt.
PB60019-01
Enter
DPNSS Integration 15-11
Octel 200/300
S.4.1