Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

YES
NO
.
h. Repeat for all ports and units until all have been tested.
3. PBX FUNCTIONAL TEST (FOR NEW INSTALL)
This test verifies that each Octel 200/300 port extension can initiate a transfer by doing a
hookswitch flash and a transfer code (or just a hookswitch flash), before entering an extension
number. Also, verify that you can reconnect to the caller when the extension called is not
answered or busy.
a.
Connect phone B to the modular adapter position associated with port 1 of the Octel 200/300.
b. From phone A call the extension number associated with phone B.
c.
Answer phone B and perform a hookswitch flash.
d. Does the PBX provide stutter or solid dial tone after the hookswitch flash?
YES
NO
e.
After several ringbacks have occurred (fewer than the PBX configured number of ringbacks
before RNA forwarding), perform a hookswitch flash and reconnect code, if required, to
reconnect to phone A.
f.
Did phone C stop ringing? Did you get reconnected to phone A, that was on hold?
YES
NO
.
PB60019-01
Continue the procedure until all ports are tested.
'
Determine the cause and correct the problem before continuing.
'
If only one display phone is available, connect the phone to Link 1, perform all the tests
and then connect the phone to Link 2 and repeat the tests.
Enter the extension number associated with phone C.
'
' Stop and correct the problem before continuing.
Connect phone B to the next Octel 200/300 port extension and continue until all
'
extensions for Octel 200/300 ports have been tested.
Determine the cause and correct the problem before continuing.
'
The extension number connected to phone C should start with the same first digit
configured in the
able.
USER T
Rolm CBX Adaptive Integration
Octel 200/300
8.1-17
S.4.1