The following are definitions of the fields displayed when listing the state of the MIC board.
Card ID
Card Status
Diagnostic
Link (1−2) Status
PB60019-01
Mitel SX-100/SX-200 Analog Adaptive Integration
The CARD ID states the type of integration card.
There are four possible states for the card:
The MIC is down and not responding to the
CARD DOWN
software.
The Octel 200/300 is downloading to the
DOWNLOAD CODE
MIC.
The Octel 200/300 software setting up MIC
INITIALIZATION
operation parameters.
The MIC is operational.
CARD UP
The MIC firmware reports the diagnostic code to the Octel 200/300
CPU.
If there are no errors, the DIAGNOSTIC = OK.
-
If an error is found, the DIAGNOSTIC = ERROR DETECTED,
-
CODE = XX.
If this happens, refer to the Installation and Maintenance volume,
System Errors and Traffic Pegs chapter, for more information.
There are six possible states for the digit display set links to the MIC:
Link operating properly. No call.
IDLE
Link is handling a call
ACTIVE
Link is performing message waiting
MSG WAIT
indication
Link is not receiving commands.
DOWN
Link loop current is not detected. Link is
DEAD
probably disconnected.
MIC firmware is performing link
INIT
initialization.
Only the DOWN and DEAD states are error conditions. If found, check
the PBX and the wiring.