Avaya Octel 200 Installation And Maintenance Manual page 700

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

12.1-38
Integration Volume
c.
After phone B stops ringing, does the Octel 200/300 respond with the prompt, "Extension EXTB
is unavailable. Please leave a message at the tone. . . "?
NO
d. Enter
5. INTERNAL CALL TO A BUSY EXTENSION
This test verifies that the Octel 200/300 correctly processes a call forwarded from a busy
extension.
a.
Take phone B off-hook so that it appears busy.
b. From phone A, call phone B. Does the Octel 200/300 answer with the prompt, "Extension EXTB
is unavailable. Please leave a message at the tone. . . "?
NO
c.
Enter
6. INTERNAL CALL — FAIL−SAVE OPERATION FOR ALL PORTS BUSY
This test verifies that calls to the Octel 200/300 redirect to the designated fail-safe position when
the ports are in use.
a.
Verify that System Parameters 45 and 46 are set to NONE.
b. Put the Octel 200/300 ports in the FWD state by entering, at the @ prompt
CD x y z
where x is the slot number, y is the first port, and z is the last port to forward.
c.
Using phone C, call the Octel 200/300 extension pilot number. Does the operator answer?
NO
d. Cancel the FWD state by entering
CU x y z
where x is the slot number, y is the first port, and z is the last port to cancel forwarding.
7. EXTERNAL TRUNK CALL TO THE OCTEL 200/300
This test verifies that the Octel 200/300 correctly processes calls from trunks that have been
auto-terminated to the Octel 200/300 hunt group. Be sure to test all such trunk groups.
.
a.
From phone A, call outside of the PBX and back in on a trunk that terminates to the Octel
200/300. Does the Octel 200/300 answer with the greeting configured for the trunk?
NO
Octel 200/300
S.4.1
Determine the cause, and correct the problem before continuing.
'
to exit from the Octel 200/300 and hang up phone A.
9
9
Determine the cause and correct the problem before continuing.
'
to exit from the Octel 200/300. Hang up phone A and phone B.
9
9
Determine the cause, and correct the problem before continuing.
'
1-800 (InWATS) lines can be tested individually, even if they are bands from other areas, by
using planned test numbers. Get these numbers from the CO if you do not already know them.
Determine the cause, and correct the problem before continuing.
'
PB60019-01