10.2-36 Integration Volume
Integration Pegs
Octel 200/300
S.4.1
There are two types of integration pegs: Link Independent and Link
Dependent. Link-Independent pegs occur on any link, while
Link-Dependent pegs occur on the specified link. Integration pegs are
listed by using the LIST INTEGRATION command.
LINK-INDEPENDENT PEGS. The following link-independent pegs
are listed by the LIST INTEGRATION command.
PEG NAME
1
REPLY ERROR
2
REQUEST ERROR
LINK-DEPENDENT PEGS. The following link-dependent pegs are
listed by the LIST INTEGRATION command. Each link has its own
pegs.
PEG NAME
1
DEAD ERROR
2
INIT PROC ERROR
3
VCU CTRL ERROR
4
GLARE COUNT
5
MSG WT ERROR
6
SOURCE ERROR
7
DEST ERROR
8
RE-RING ERROR
DESCRIPTION
Number of times the MIC timed out
waiting for the Octel 200/300 to pro-
cess a reply.
Number of times the MIC firmware
received an invalid request.
DESCRIPTION
Number of times the MIC firmware
reported the link to be dead.
Number of times the MIC link had
to retry part of its initialization pro-
cedure.
Number of times the MIC link's call
processing routine saw an unex-
pected VCU control event.
Number of times that the Octel
200/300 went off-hook on this port
to make an outcall and the MIC
firmware saw a call come in at the
same time.
Number of times the MIC detected
an error while trying to control a
message waiting indicator (this does
not include Message Waiting Not
Configured or Message Waiting Not
Able to Make).
Number of times the MIC firmware
could not identify the source of a
call.
Number of times the MIC firmware
could not identify the destination of
a forwarded call.
Number of times the firmware saw a
call ring in immediately after anoth-
er call was ringing in without the
line indicator showing an idle line.