Avaya Octel 200 Installation And Maintenance Manual page 694

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

12.1-32
Integration Volume
d. Look at the displays of ringing lines on the digital phone. The second line of the display should
contain this information:
a = Test A EXTA to Test B EXTB
If the display does not contain this information, determine the cause, and correct the problem
before continuing.
e.
Answer the call on phone C. Verify the talk path. Hang up phone A and phone C.
3. PBX RING-NO-ANSWER FORWARD TEST
This test verifies that a call to a ring-no-answer (RNA) extension forwards to the Octel 200/300
access number.
a.
Connect the modular adapter to the 25-pair cable associated with the configured slot.
b. Connect one digital phone to the jack position of the adapter that corresponds to port 1.
c.
Make sure phone C is on-hook.
d. From phone A, call the extension number of phone B. Does phone B ring?
NO
e.
After the number of rings configured for RNA in phone B's coverage path, phone B should stop
ringing and phone C should ring.
NO
f.
Look at the displays of ringing lines on the digital phone. The second line of the display should
contain this information:
a = Test A EXTA to Test B EXTB
If the display does not contain this information, determine the cause, and correct the problem
before continuing.
g. Answer the call. Hang up phone A and phone C.
4. PBX FORWARD ALL CALLS TEST
This test verifies that an extension can forward all calls to the Octel 200/300 access number.
a.
Connect the modular adapter to the 25-pair cable associated with the configured slot.
b. Connect one digital phone to the jack position of the adapter that corresponds to port 1.
c.
Set phone B to send all calls to coverage.
d. Using phone A, call the extension of phone B. Does phone C start to ring?
NO
Octel 200/300
S.4.1
Determine the cause, and correct the problem before continuing.
'
Determine the cause, and correct the problem before continuing.
'
Determine the cause, and correct the problem before continuing.
'
XXX
d
PB60019-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octel 300

Table of Contents