Octel 200/300 Requirements; Octel 200/300 Configuration Changes To Mwi - Avaya Octel 200 Installation And Maintenance Manual

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

Octel 200/300 Installation Checklist
Item Description
1.
List the database. Highlight areas where changes are
required.
2.
Make note of the following definitions for port
Number of ports
-
Port extension number
-
3.
If different company greetings will be used, enter the
Access Code for each route into the TRUNK GROUP
Table. Obtain Access Code numbers from M1 vendor.
4.
Set the ring cycle to be one less than the ring cycle in
the M1.
Table 11-7 Octel 200/300 Configuration Changes to MWI
Item
Description
1.
Modify System Parameter 9 to be 700 (increase flash
time).
2.
Modify System Parameter 85 to be NONE (recon-
nect code after third party disconnect).
Modify System Parameter 116 to be YES.
3.
4.
Add Attribute 9 to the COS of all mailboxes requir-
ing message waiting notification.
5.
All ports should be configured for OUTCALL. (If
not ALL can be YES for OUTCALL, then configure
the higher number ports to be YES).
PB60019-01
Table 11-6 Octel 200/300 Requirements
Meridian 1 Adaptive Integration
Command
Complete
L ALL
.L SLOT
.A TRUNK
.M INFO
Index #7
Command
Complete
.M SYS 9
.M SYS 85
.M SYS 116
.A COS
.M SLOT
Octel 200/300
11-43
S.4.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octel 300

Table of Contents