10.3.7 MITEL SX-2000 MAINTENANCE
The following are the maintenance commands for the Mitel SX-2000 integration.
TEST INTEGRATION
TE INT x 1 or
TE INT x
LIST INTEGRATION
L INT x 1
CLEAR INTEGRATION
C INT x 1
PB60019-01
This command tells the MIC to run its link selftest. The form of the
command is
TE INT x 1
where x is the slot number.
Any hardware errors found are logged in the Hardware Error Table.
Refer to the Installation and Maintenance volume — System Errors and
Traffic Pegs.
This command resets the MIC board and takes approximately 30
seconds. The form of the command is
TE INT x 1 2
where x is the slot number, and 2 is the reset flag.
This command lists the current state of the MIC board, the diagnostic
status, the status of the links, and the pegs. The form of the command is
L INT x 1
where x is the slot number.
An example listing is
@L INT X
********** INTEGRATION STATUS **********
CARD ID = Mitel
CARD STATUS = UP
DIAGNOSTIC = OK
LINK 1 STATUS = ACTIVE
LINK 2 STATUS = IDLE
LINK 3 STATUS = IDLE
LINK 4 STATUS = MSG WAIT
PEGS:
MM/DD
HH:MM
INDEPENDENT = 0 0 0 0 0
LINK 1 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 2 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 3 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 4 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This command clears the MIC board pegs. The form of the command is
C INT x 1
where x is the slot number.
Mitel SX-2000 Adaptive Integration