7.3-48
Integration Volume
Item Description
1.
Forward the ports.
2.
Plug the card into the configured slot . Refer to the power-
on routine and monitor the LEDs.
3.
Plug the 25-pair cable into the ATTIC slot. Monitor the
LEDs.
Item Description
1.
Mailbox and extension numbers must match.
2.
Modify System Parameter 3 (PBX type is System 85).
3.
Modify System Parameter 85 to be NONE (reconnect code
after third party disconnect).
4.
Modify System Parameter 116 to be .
5.
Modify System Parameter 117 to be 5 (ringbacks before
answering).
6.
Add Attribute 15 to the COS of all mailboxes associated
with extensions that forward to the Octel 200/300.
7.
All ports should be configured in AX mode.
8.
Add a COS with Attribute 58 to those ports that do not
require integration.
9.
Configure the TRUNK GROUP Table if different require-
ments than for a port. A unique COS should be assigned
for these trunks.
10.
For mailboxes requiring Quick Greeting Activation,
modify INFORMATION Table Index 25 to be YES.
11.
Configure all Octel 200/300 ports YES for outcall.
12.
For collocated system, modify System Parameter 130 to
YES.
Octel 200/300
S.4.1
Table7.3-9 Installing the ATTIC Board
Table7.3-10 Configuration Changes to CPI
Command
Complete
@ TE C 1
Command
Complete
.M SYS 3
.M SYS 85
.M SYS 116
.M SYS 117
.A COS
.M SLOT
.A COS
.A TRUNK
.M INFO
Index 25
.M SLOT
.M SYS 130