10.3-50
Integration Volume
Table 10.3-4 Octel 200/300 Configuration Changes for MWI and CPI
Item
Description
16.
Modify System Parameter 106 on the SLOTS Table for MIW,
if applicable.
17.
Modify System Parameter 116 to be YES.
18.
Modify System Parameter 117 to 5.
19.
Modify System Parameter 131 to be YES.
20.
For SX-2000 systems not using the COV Voice Mail Port class
of service option, modify System Parameter 170 to be YES.
21.
Modify the value of System Parameter 191 to be the hour
when the Octel 200/300 should automatically update Message
Waiting Indicators.
22.
Modify the SLOTS Table so that all integrated ports are in AX
mode and so that all ports are configured for outcall except the
port used for MWI. Set testing to NO for all ports.
Table 10.3-5 After All Octel 200/300 Configuration Changes are Complete
Item
Description
1.
When you exit UPDATE after making the necessary changes, Octel
200/300 prompts:
FOR CHANGES TO TAKE EFFECT, SYSTEM MUST BE RESTARTED.
2.
Restart the system.
Item
Description
1.
Configure the required test extensions.
2.
Perform pre-installation testing.
3.
Install the MIC boards in the Octel 200/300 and connect the Superset
lines.
4.
Perform Adaptive Integration operational tests.
Octel 200/300
S.4.1
Table 10.3-6 Installation and Testing
Command
Complete
.M SYS
106
.M SYS
116
.M SYS
117
.M SYS
131
.M SYS
170
.M SYS
191
.M SLOT
Complete
Complete