7.3-24
Integration Volume
System Parameters
TRUNK GROUP Table
Octel 200/300
S.4.1
System Parameter 3 — PBX MODEL
Select the model number of the telephone system from the list.
System Parameter 116 — INTEGRATION TYPE
Modify System Parameter 116 to be YES (System 85).
System Parameter 117 — RINGBACKS BEFORE ANSWERING
AX PORT
Modify System Parameter 117 to be 5. This gives extra time to receive
the call records from the PBX.
.
Octel 200/300 normally answers the call immediately within one
ring upon receiving a call record from the ATTIC. This system
parameter provides a fail-safe mode of operation. The ports
answer calls in AX mode in the event that Octel 200/300 does
not receive call information from the digit display links.
The TRUNK GROUP Table specifies call processing parameters for
different trunk groups by Octel 200/300 COS.
Configure Trunk Group 0 (zero) with a greeting for use with internal
forwarded calls received without extension numbers. The greeting
should specify that the called party does not have a mailbox on the
system.
Refer to the Configuration volume, Trunk Group Table chapter, for
more information.