Table 9-8 The Octel 200/300 Configuration Changes for CPI
Item
Description
1.
Modify System Parameter 3 —
type for the Millennium.
2.
Modify System Parameter 51 —
WITH PBX
3.
Modify System Parameter 99 —
ANSWERING CX PORT
4.
Modify System Parameter 100 —
ANSWERING MX PORT,
5.
Modify System Parameter 117 —
ANSWERING AX PORT,
6.
Modify System Parameter 130 —
FORWARDED CALLS,
7.
Modify System Parameter 180 —
FOR PBX INTEGRATION
= 8 bits/no parity.
8.
Assign COS Attribute 15 —
EXTENSION.
9.
Configure all ports that answer calls forwarded to the Octel
200/300 for AX mode.
10.
Set the Ring No Answer Count to 3.
Table 9-9 After All Changes Have Been Made for MWI and CPI
Item
Description
1.
Exit
UPDATE
200/300 prompts:
FOR CHANGES TO TAKE EFFECT, SYSTEM MUST
BE RESTARTED.
2.
Restart the system.
3.
Test to ensure that message waiting indication and/or called
party identification are operational.
PB60019-01
PBX TYPE
RS-232 INTEGRATION
, to YES.
RINGBACKS BEFORE
, to 5.
RINGBACKS BEFORE
to 5.
RINGBACKS BEFORE
to 5.
SEND DTMF A FOR
to YES
.
RS-232 BYTE FORMAT
to 0 or 1. 0 = 7 bits/even parity; 1
TRANSFER TO A RINGING
after making the necessary changes. The Octel
Cortelco Millennium Adaptive Integration 9-19
Command
, to 01, the PBX
.M SYS 3
.M SYS 51
.M SYS 99
.M SYS
100
.M SYS
117
.M SYS
130
.M SYS
180
.A COS
.M
SLOT
.M INFO
Index 7
Command
@RESTA
Complete
Complete
Octel 200/300