Avaya Octel 200 Installation And Maintenance Manual page 494

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

10.1-40 Integration Volume
10.1.7 MITEL SX-200 DIGITAL MAINTENANCE
The following are the maintenance commands for the Mitel SX-200 Digital integration.
TEST INTEGRATION
TE INT x 1 or
TE I x 1
TE INT x 1 2
LIST INTEGRATION
L INT x 1
CLEAR INTEGRATION
C INT x 1
Octel 200/300
S.4.1
This command tells the MIC to run its link selftest. The form of the
command is
TE INT x 1
where x is the slot number.
Any hardware errors found are logged in the Hardware Error Table.
Refer to the Installation and Maintenance volume, System Errors and
Traffic Pegs chapter, for more information.
This command resets the MIC board and takes approximately 30
seconds. The form of the command is
TE INT x 1 2
where x is the slot number, and 2 is the reset flag.
This command lists the current state of the MIC board, the diagnostic
status, the status of the links, and the pegs. The form of the command is
L INT x 1
where x is the slot number.
An example listing for the Octel 300 is as follows:
@L INT 4 1
********** INTEGRATION STATUS **********
CARD ID = Mitel
CARD STATUS =
UP
DIAGNOSTIC = OK
LINK 1 STATUS = ACTIVE
LINK 2 STATUS = IDLE
LINK 3 STATUS = IDLE
LINK 4 STATUS = ACTIVE
PEGS:
MM/DD
HH:MM
INDEPENDENT = 0 0 0 0 0
LINK 1 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 2 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 3 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 4 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
This command clears the MIC pegs. The form of the command is
C INT x 1
where x is the slot number.
PB60019-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octel 300

Table of Contents