12.3-10
Integration Volume
The following are examples of invalid names.
Invalid Names for
Extension 1234
Invalid Names for
Trunk Group 61
Invalid Names for Port
3333
APIC Port Digital Phone Extensions Configuration Changes
A digital telephone station must be allocated for each APIC port. These stations must be properly
configured as 7405D sets in the System 85 to interface with the Octel 200/300.
.
For proper functionality, each port must be set up to do either call processing or message waiting.
Sizing the message server for call processing applications would reference just the call processing
ports.
The following can be used to size the number of message waiting links required. This is only a
guideline; the actual number of links needed depends on the number of users, message traffic and
desired message waiting lamp performance.
-
-
-
-
-
-
When links are configured in the SLOT Table, assign them in the following manner: start with
link 12 on the last APIC card and work towards the first APIC card. If additional links are
desired, start with link 8 on the last APIC card and work again toward the first card. This will
allocate message waiting activity evenly across processors in the APIC card.
There are several different interfaces or configuring the System 85. If you are using the SMT (System
Management Terminal), refer to Appendix A, at the end of this chapter. If you are using CSM
(Centralized System Management), refer to Appendix B, at the end of this chapter.
Octel 200/300
S.4.1
Joe Jones
Dept. 4 Joe 1234
T-1234 Joe Jones
Joe 1234 Jones
Josephine Johnson 123
Incoming Trunk
Trunk 61
999 First T-61
333
Port1 D-3333
1−12 ports
1 link
13−24 ports
2 links
25−48 ports
3 links
49−72 ports
4 links
73−96 ports
5 links
97−128 ports
6 links
No extension number.
A number precedes the extension
number and will be decoded as
extension 4.
Contains trunk ID "T-".
Invalid extension number.
Name with extension exceeds 16 char-
acters.
No trunk number.
Missing "T-".
Number precedes trunk group.
Missing "D-".
A number precedes D-XXXX string
and will be decoded as extension.