Actual Installation - Avaya Octel 200 Installation And Maintenance Manual

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

5-16
Integration Volume

Actual Installation

Item
1.
2.
3.
4.
5.
Item
1.
2.
3.
Octel 200/300
S.4.1
Table 5-4 Actual Installation
Description
Connect the NEAX-2400 data link via the special cables to the Octel 200/300
upper RS-232C port B.
One data link must be configured for each Octel 200/300 cabinet.
Refer to the Octel 200/300/NEAX-2400 Installation section in this chapter for
cable specifications for the configuration for the Octel 200/300 NEC 2400
MCI.
Every port/extension associated with the data link must be in the same Octel
200/300 UCD group.
Mailbox/extension numbers must match for both MWI and CPI.
Table 5-5 The Octel 200/300 Configuration Changes for MWI
Description
Modify System Parameter 51 —
RS-232 INTEGRATION WITH PBX to YES.
Modify System Parameter 180 —
RS-232 BYTE FORMAT FOR PBX INTEGRATION to 0
or 1.
0 = 7 bits/even parity; 1 = 8 bits/no parity.
Assign COS Attribute 9 —
LAMP OR DISPLAY PHONE MESSAGE WAITING only
to mailboxes that will have MWI activated to light lamps.
Complete
Command
Complete
.M SYS 51
.M SYS 180
.A COS
PB60019-01