Avaya Octel 200 Installation And Maintenance Manual page 498

Message servers
Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

10.1-44 Integration Volume
10.1.8 INSTALLATION CHECKLIST
This section offers a checklist of issues relating to the Octel 200/300 and the Mitel SX-200 Digital. The
list is presented in the order that the installation process should be followed. For details regarding any
topic, refer to the sections in this chapter pertaining to the issue.
Pre-Installation
Item
Description
1.
The Mitel SX-200 Digital must provide a Superset 4 line for each Octel
200/300 MIC port.
2.
Confirm the Mitel SX-200 Digital software level for release-specific
configuration issues.
3.
The Mitel SX-200 Digital must have two unassigned COS available,
one for CPI and one for MWI.
Item
Description
1.
Before making any changes, print out the database. Verify and highlight
areas where changes are required.
2.
Configure the MIC Superset extension used for MWI.
3.
Configure the MIC Superset extensions used for CPI.
4.
Configure trunks that will be answered by the Octel 200/300.
5.
Configure individual station extensions for Adaptive Integration.
6.
Make sure individual station extensions are forwarded to the Octel
200/300 hunt group for call coverage.
Octel 200/300
S.4.1
Table 10.1-2 Mitel SX-200 Digital Requirements
Table 10.1-3 Mitel SX-200 Digital Configuration
Complete
Complete
PB60019-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Octel 300

Table of Contents