5. INTERNAL CALL TO A BUSY EXTENSION
This test verifies that the Octel 200/300 correctly processes a call forwarded from a busy
extension.
a.
Set phone B to forward to the Octel 200/300 on a busy condition by entering the feature access
code for Call Forwarding − Busy followed by the Octel 200/300 access number. After setting
forwarding for phone B, leave phone B off-hook so that it appears busy.
b. From phone A, call phone B. Does the Octel 200/300 answer with the prompt, "Extension
EXT-B is unavailable. Please leave a message at the tone. . . "?
NO
c.
While still connected to the Octel 200/300, enter the mailbox number of mailbox B. This should
be the same as the extension number of phone B. Does the Octel 200/300 respond with the
prompt, "Thank you. Just a moment. . . "?
NO
d. After a short interval, does the Octel 200/300 respond with, "Extension EXT-B is unavailable.
Please leave a message at the tone. . . "?
NO
e.
Enter
6. FAIL-SAFE OPERATION FOR ALL PORTS BUSY (GENERIC 1003 ONLY)
This test verifies that calls to the Octel 200/300 redirect to the designated fail-safe position when
all MIC call appearances are in use. This test applies only to PBXs with Generic 1003 or later,
which permits configuration of a hunt group overflow position.
.
a.
Put the Octel 200/300 ports in FWD state by entering at the @ prompt
TE C 1
b. Using phone A, call the extension of the Octel 200/300 hunt group. Be sure that you reach the
position specified for overflow in the Octel 200/300 hunt group. If not, correct the problem
before continuing.
c.
Hang up phone A.
d. Cancel the Octel 200/300 ports FWD state by entering at the @ prompt
TE C 2
PB60019-01
Determine the cause and correct the problem before continuing.
'
Determine the cause and correct the problem before continuing.
'
Determine the cause and correct the problem before continuing.
'
to exit from the Octel 200/300. Hang up phone A and phone B.
9
9
Skip this test if the PBX software level is Generic 1000, Generic 1001, or Generic 1002.