For information on hardware errors regarding integrated systems, refer to the Installation and
Maintenance volume, System Errors and Traffic Pegs chapter, for more information.
This section offers a checklist of issues relating to the Octel 200/300 and the Mitel SX-100/SX-200
Analog. The list is presented in the order that the installation process should be followed. For details
regarding any topic, refer to the sections in this chapter pertaining to the issue.
PB60019-01
Mitel SX-100/SX-200 Analog Adaptive Integration
PEG
NAME
9
MSG WT NOT CONFI-
GURED
10
RESEND ERROR
11
CP MW ERROR
12
DISPLAY ERROR
13
ANSWER ERROR
15
DOWN ERROR
16
INT ERROR
DESCRIPTION
Number of times the MIC made a
call to toggle a message waiting in-
dicator and could not identify the
status of the indicator.
Number of times the firmware saw
no response to a keypress after a
timeout and had to resend the key-
press.
Number of times that a port confi-
gured as a message waiting port re-
ceived an incoming call, or a port
configured as a call processing port
received a message waiting request.
Number of times a call rang in with
an unrecognizable display.
Number of times the VCU went off-
hook before the firmware finished
reading the display.
Number of times the MIC firmware
reported the link to be down.
Miscellaneous firmware error has
occurred.
Octel 200/300
10.2-37