7.2-48
Integration Volume
Card Status
Diagnostic
Link (1-2) Status
Integration Pegs
Octel 200/300
S.4.1
There are four possible states for the card:
The ATTIC is down and not responding to the
CARD DOWN
software.
Code is downloading to the ATTIC.
DOWN LOAD
INITIALIZATION The Octel 200/300 software is downloading code
to the card and setting up operation parameters.
The ATTIC is operational.
CARD UP
The diagnostic code is read from the ATTIC card.
If there are no errors, the DIAGNOSTIC = OK.
-
If an error is found, the DIAGNOSTIC = ERROR DETECTED,
-
CODE = XX.
If this happens, refer to the Installation and Maintenance volume,
Traffic Pegs, Boot ROM, Hardware Errors chapter, for more
information.
There are five possible states for the digit display set links to the
ATTIC:
Link operating properly. No call.
IDLE
Link is handling a call.
ACTIVE
Link is performing message waiting indication.
MSG WAIT
Link is performing SELFTEST.
SLFTST
The link is not getting call information or
DEAD
commands. The link is probably disconnected.
Only the DEAD state is an error condition. If it is found, check the PBX
and the wiring.
Integration pegs are defined into two types — Link Independent and
Link Dependent. Link Independent can occur on either link, while Link
Dependent occurs on the link that is pegged. Integration pegs are listed
by using the L INT command.
LINK-INDEPENDENT PEGS. The following independent pegs are
listed by the LIST INTEGRATION command.