10.1-22 Integration Volume
TRUNK GROUP Table
Octel 200/300
S.4.1
System Parameter 170 — INTEGRATION LAMP ON/OFF LINK
MUST MATCH
Modify the value of System Parameter 170 to be YES.
System Parameter 191 — HOUR TO REACTIVATE MSG WTG
INDICATORS
Modify System Parameter 191 to be the hour of the day when the Octel
200/300 will perform automatic reactivation of message waiting
indicators. Because the PBX automatically cancels message waiting for
Superset 4 display telephones after 24 hours, System Parameter 191 is
required. System Parameter 191 reactivates the message waiting
indicator every 24 hours.
The TRUNK GROUP Table specifies call processing parameters for
different trunk groups by Octel 200/300 COS.
Configure Trunk Group 0 with a greeting for use with internal
forwarded calls received without extension numbers. The greeting
should specify that the person called does not have a mailbox on the
system.
.
For all software release levels lower than Generic 1003, Called
Party Identification identifies incoming trunks by their individual
trunk numbers, not by PBX trunk group numbers. This requires
that each individual trunk have its own entry in the Octel
200/300 TRUNK GROUP Table.
With Generic 1003, trunks may be identified by trunk group,
provided that the trunk group is assigned a name that follows the
Naming Conventions at the beginning of the Mitel SX-200
Digital Configuration section of this chapter. A trunk that is not
part of a trunk group is identified by individual trunk number.
All trunk groups will also be identified by individual trunk
number if Generic 1003, release E96.7 or later is used because of
the COS option, COV Voice Mail Port.
The Octel 200/300 identifies calls from the attendant as coming from
Trunk Group 00, since a call from the attendant cannot be identified by
extension number. Refer to Direct Internal Calls in this section.
Refer to the Configuration volume, Trunk Group Table chapter, for
more information.