Display Schedule Reboot - H3C S7500E Series Command Manual

Hide thumbs Also See for S7500E Series:
Table of Contents

Advertisement

Command Manual – System Maintaining and Debugging
H3C S7500E Series Ethernet Switches
Parameters
power-id: Power supply number.
Description
Use the display power to display the status of the power supply of a device.
Examples
# Display the status of the power supply of a device.
<Sysname> display power
Power
Power
The above information indicates that power supply 1 works normally, and power supply
2 is absent.

3.1.11 display schedule reboot

Syntax
display schedule reboot
View
Any view
Parameters
None
Description
Use the display schedule reboot command to display the device reboot time set by
the user.
Related commands: schedule reboot at and schedule reboot delay.
Examples
# Display the reboot time of a device.
<Sysname> display schedule reboot
System will reboot at 16:00:00 2006/03/10 (in 2 hours and 5 minutes).
The above information indicates the system will reboot at 16:00:00 on March 10, 2006
(in two hours and five minutes).
1 State: Normal
2 State: Absent
Chapter 3 Device Management Commands
3-11

Advertisement

Table of Contents
loading