Command Manual – Login
H3C S7500E Series Ethernet Switches
View
AUX interface view
Parameters
speed-value: Transmission speed (in bps). This argument can be 300, 600, 1200, 2400,
4800, 9600, 19,200, 38,400, 57,600, 115,200 and defaults to 9,600.
Description
Use the speed command to set the transmission speed of the user interface.
Use the undo speed command to revert to the default transmission speed.
Note:
After you use the speed command to configure the transmission speed of the AUX user
interface, you must change the corresponding configuration of the terminal emulation
program running on the PC, to keep the configuration consistent with that on the switch.
Examples
# Set the transmission speed of the AUX user interface to 9600 bps.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] user-interface aux 0
[Sysname-ui-aux0] speed 9600
1.1.25 stopbits
Syntax
stopbits { 1 | 1.5 | 2 }
undo stopbits
View
AUX interface view
Parameters
1: Sets the stop bits to 1.
1.5: Sets the stop bits to 1.5.
2: Sets the stop bits to 2.