Ramp-function generator active
Mop configuration
- ... -
2
p1030 [D] (0000 0110 bin)
3
Ramp-function generator is
4
STW setpoint chan
r1198
Mop raise
r1198
.13
p1035 [C]
[2505.7]
(2090.13)
STW setpoint chan
r1198
Mop lower
r1198
.14
p1036 [C]
[2505.7]
(2090.14)
MotP n_max
-210000.000 ... 210000.000 [1/min]
p1037 [D] (0.000)
<1>
MotP n_min
-210000.000 ... 210000.000 [1/min]
p1038 [D] (0.000)
<1>
<1>
For automatic commissioning, p1037 and p1038 are set to the maximum motor frequency or to the
rated motor frequency, provided that f_max_mot has not been specified.
<2>
If initial rounding-off is active (p1030.2 = 1), the selected ramp-up/down times are exceeded
accordingly.
<3>
Only effective if p1030.0 = 0.
1
2
Setpoint channel
Motorized potentiometer
Data save active
0
The setpoint for the motorized potentiometer is not saved and after ON is entered using p1040.
1
The setpoint for the motorized potentiometer is saved in a ashion after OFF and after ON set to the saved value.
Automatic mode
0
Without ramp-function generator in automatic mode (ramp-up/ramp-down time = 0).
1
With ramp-function generator in automatic mode.
Initial rounding-off active
0
Without initial rounding.
1
With initial rounding. The ramp-up/down time set is exceeded accordingly.
Save in NVRAM active
0
Not saved in the NVRAM (NVRAM = Non Volatile Random Access Memory).
1
Save in NVRAM active.
0
Ramp-up encoder inactive with pulse inhibit.
always active
1
The ramp-up encoder is calculated independently of the pulse enable.
0
Old value is kept
-1
1
Mop manual/auto
p1041 [C]
0 0
0 1
0
-1
1
1 0
1 1
MotP inv
p1039 [C]
(0)
Mop auto setpoint
p1042 [C]
(0)
3
4
p1030.1
&
(0)
0.000 ... 1000.000 [s]
Mop n_set bef RFG [1/min]
r1045
0
1
x
1
0
f_max (reference value for
ramp-function generator p1082)
[3050.5]
Mop set val
p1044 [C]
(0)
MotP acc set val
p1043 [C]
(0)
[2634.8] 1: OFF1 enable missing (r0046.0)
0:
5
fp_3020_97_51.vsd
12.12.2012
<2>
<2>
Mop ramp-up time
Mop ramp-down time
0.000 ... 1000.000 [s]
p1047 [D] (10.000)
p1048 [D] (10.000)
y
p1082
Mop setp after
y
x
e.g. to [3030.1]
-p1082
y = 0
Mop start value
-210000.000 ... 210000.000 [1/min]
p1040 [D] (0.000)
<3>
p1030.4
0
1
6
7
Function diagram
SINAMICS G120D
V4.6
RFG [1/min]
r1050
8
- 3020 -