From the fault buffer [8060.6]
From the alarm buffer [8065.4]
From the thermal monitoring, motor [8016.8]
From the thermal monitoring, power module [8014.8]
From the thermal monitoring, motor [8016.8]
From the thermal monitoring, motor [8016.8]
1
2
Internal control/status words
Status word, faults/alarms 1 and 2
Bit No.
Status word, faults/alarms 1
0
1 = Acknowledgement running
1
Reserved
2
3
1 = Fault present
4
Reserved
5
1 = Internal signal 1 present
6
1 = Alarm present
7
8
1 = Internal signal 2 present
9
Reserved
10
11
Alarm class bit 0
Alarm class bit 1
12
Reserved
13 - 15
Bit No.
Status word, faults/alarms 2
0
...
Reserved
11
1 = Fault motor overtemperature
12
1 = Fault, thermal overload, power module
13
14
1 = Alarm motor overtemperature
15
1 = Alarm, thermal overload, power module
3
4
ZSW fault/alarm 1
r2139
r2139
r2139.0
r2139.3
r2139.6
r2139.7
r2139.8
r2139.11
r2139.12
ZSW fault/alarm 2
r2135
r2135
r2135.12
r2135.13
r2135.14
r2135.15
5
6
Function diagram
fp_2548_97_65.vsd
SINAMICS G120D
12.12.2012
V4.6
7
8
- 2548 -