Parameters
List of parameters
p0446[0...n]
Encoder SSI number of bits before the absolute value / Enc SSI bit before
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: C(4)
Units group: -
Min
0
Description:
Sets the number of bits before the absolute value in the SSI protocol.
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
For example, error bit, alarm bit or parity bit can be positioned at these bits.
p0447[0...n]
Encoder SSI number of bits absolute value / Enc SSI bit val
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: C(4)
Units group: -
Min
0
Description:
Sets the number of bits for the absolute value in the SSI protocol.
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
p0448[0...n]
Encoder SSI number of bits after the absolute value / Enc SSI bit after
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: C(4)
Units group: -
Min
0
Description:
Sets the number of bits after the absolute value in the SSI protocol.
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
For example, error bit, alarm bit or parity bit can be positioned at these bits.
p0449[0...n]
Encoder SSI number of bits filler bits / Enc SSI fill bits
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: C(4)
Units group: -
Min
0
Description:
Sets the number of filler bits for double absolute value transfer in the SSI protocol.
Dependency:
Refer to: p0429
Caution:
This parameter is automatically pre-set for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
This parameter is only of significance for p0429.2 = 1.
1-84
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
65535
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
25
Data type: Unsigned16
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
1

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all