Parameters
List of parameters
p0045
Display values smoothing time constant / Disp_val T_smooth
Access level: 3
Can be changed: U, T
Units group: -
Min
0.00 [ms]
Description:
Sets the smoothing time constant for the following display values:
r0063[1], r0068[1], r0080[1], r0082[1].
r0046.0...31
CO/BO: Missing enable sig / Missing enable sig
Access level: 1
Can be changed: -
Units group: -
Min
-
Description:
Displays missing enable signals that are preventing the closed-loop drive control from being commissioned.
Bit field:
Bit
Signal name
00
OFF1 enable missing
01
OFF2 enable missing
02
OFF3 enable missing
03
Operation enable missing
04
DC braking enable missing
10
Ramp-function generator enable missing
11
Ramp-function generator start missing
12
Setpoint enable missing
16
OFF1 enable internal missing
17
OFF2 enable internal missing
18
OFF3 enable internal missing
19
Pulse enable internal missing
20
DC braking internal enable missing
21
PU enab missing
26
Drive inactive or not operational
27
De-magnetizing not completed
28
Brake open missing
30
Speed controller inhibited
31
Jog setpoint active
Dependency:
Refer to: r0002
Note:
The value r0046 = 0 indicates that all enable signals for this drive are present.
Bit 00 = 1 (enable signal missing), if:
- the signal source in p0840 is a 0 signal.
- there is a "switching on inhibited".
Bit 01 = 1 (enable signal missing), if:
- the signal source in p0844 or p0845 is a 0 signal.
Bit 02 = 1 (enable signal missing), if:
- the signal source in p0848 or p0849 is a 0 signal.
Bit 03 = 1 (enable signal missing), if:
- the signal source in p0852 is a 0 signal.
Bit 04 =1 (DC brake active) when:
- the signal source in p1230 has a 1 signal
Bit 10 = 1 (enable signal missing), if:
- the signal source in p1140 is a 0 signal.
1-32
Calculated: -
Scaling: -
Unit selection: -
Max
10000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6714, 8012
Factory setting
4.00 [ms]
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2634
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement