List of parameters
p2203[0...n]
CO: Technology controller fixed value 3 / Tec_ctr fix val 3
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: U, T
CU240D-2_PN
Units group: 9_1
CU240D-2_PN_F
Min
-200.00 [%]
Description:
Sets the value for fixed value 3 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2204[0...n]
CO: Technology controller fixed value 4 / Tec_ctr fix val 4
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: U, T
CU240D-2_PN
Units group: 9_1
CU240D-2_PN_F
Min
-200.00 [%]
Description:
Sets the value for fixed value 4 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2205[0...n]
CO: Technology controller fixed value 5 / Tec_ctr fix val 5
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: U, T
CU240D-2_PN
Units group: 9_1
CU240D-2_PN_F
Min
-200.00 [%]
Description:
Sets the value for fixed value 5 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2206[0...n]
CO: Technology controller fixed value 6 / Tec_ctr fix val 6
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: U, T
CU240D-2_PN
Units group: 9_1
CU240D-2_PN_F
Min
-200.00 [%]
Description:
Sets the value for fixed value 6 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
1-298
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
30.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
40.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
50.00 [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 7950
Factory setting
60.00 [%]