Tec_ctr mop config
p2230 [D] (0000 0100 bin)
0
1
Initial rounding-off active
2
Non-volatile data save active
3
Ramp-function generator is always active
4
Tec_ctrl mop raise
p2235 [C]
(0)
Tec_ctrl mop lower
p2236 [C]
(0)
Tec_ctrl mop max
-200.00 ... 200.00 [%]
p2237 [D] (100.00)
Tec_ctrl mop min
-200.00 ... 200.00 [%]
p2238 [D] (-100.00)
<1>
For p2230.0 = 0, this setpoint is entered after ON.
<2>
If initial rounding-off is active (p2230.2 = 1), the selected ramp-up/down times are exceeded accordingly.
1
2
Technology controller
Motorized potentiometer
Data save active
0
The setpoint for the motorized potentiometer is not saved and after ON is entered using p2240.
1
The setpoint for the motorized potentiometer is saved after OFF and after ON is entered using r2231.
0
Without initial rounding.
1
With initial rounding. The ramp-up/down time set is exceeded accordingly.
0
Non-volatile data save not activated
1
The setpoint for the motorized potentiometer is saved in a non-volatile fashion (for p2230.0 = 1)
0
Ramp-up encoder inactive with pulse inhibit.
1
The ramp-up encoder is calculated independently of the pulse enable.
Old value is kept
0 0
Tec_ctr mop befRFG [%]
0 1
r2245
1 0
1 1
Missing enable sig
r0046
r0046
.0
3
4
<2>
<2>
Tec_ctr mop t_r-up
Tec_ctrMop t_rdown
0.0 ... 1000.0 [s]
0.0 ... 1000.0 [s]
p2247 [D] (10.0)
p2248 [D] (10.0)
y
p2237
x
-p2238
y = 0
Tec_ctrl mop start
-200.00 ... 200.00 [%]
p2240 [D] (0.00)
1 = OFF1, enable missing
Tec_ctrl mop mem [%]
r2231
5
6
fp_7954_97_61.vsd
12.12.2012
V4.6
Tec_ctr mop aftRFG [%]
y
r2250
x
<1>
7
8
Function diagram
- 7954 -
SINAMICS G120D