Parameters
List of parameters
r9725[0...2]
SI Motion diagnostics STOP F / SI Mtn Diag STOP F
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
-
Description:
Re index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
Processor 1 signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the crosswise data comparison between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
Re index 1:
Displays the value from processor 1 that resulted in the STOP F.
Re index 2:
Displays the value from processor 2 that resulted in the STOP F.
Index:
[0] = Message value for CDC
[1] = Processor 1 CDC actual value
[2] = Processor 2 CDC actual value
Dependency:
Refer to: C01711
Note:
The significance of the individual message values is described in message C01711.
CDC: Crosswise Data Comparison
Re Index 1, 2:
When Safety message C01711 with message value >= 1000 occurs, these indices are not supplied with values.
r9728[0...2]
SI Motion actual checksum SI parameters (processor 1) / SI Mtn act CRC P1
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
-
Description:
Displays the checksum over the checked Safety Integrated parameters of the motion monitoring functions (actual
checksum).
Index:
[0] = Checksum over SI parameters for motion monitoring
[1] = Checksum over SI parameters for actual values
[2] = Checksum over SI parameters for hardware
Dependency:
Refer to: p9729
Refer to: F01680
p9729[0...2]
SI Motion setpoint checksum SI parameters (processor 1) / SI Mtn setp CRC P1
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
0000 hex
Description:
Sets the checksum using the checksum-tested Safety Integrated parameters for motion monitoring functions (refer-
ence checksum).
1-434
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0000 hex