Parameters
List of parameters
p1530[0...n]
Power limit motoring / P_max mot
Access level: 2
Can be changed: U, T
Units group: 14_5
Min
0.00 [kW]
Description:
Sets the power limit when motoring.
Dependency:
Refer to: p0500, p1531
Note:
The power limit is limited to 300% of the rated motor power.
p1531[0...n]
Power limit regenerative / P_max gen
Access level: 2
Can be changed: U, T
Units group: 14_5
Min
-100000.00 [kW]
Description:
Sets the regenerative power limit.
Dependency:
Refer to: r0206, p0500, p1530
Note:
The power limit is limited to 300% of the rated motor power.
For power units without energy recovery capability, the regenerative power limit is preset to 30 % of the power
r0206[0]. For a braking resistor connected to the DC link (p0219 > 0), the power limit when generating is automati-
cally adapted.
For power units with energy recovery, the parameter is limited to the negative value of r0206[2].
r1533
Current limit torque-generating total / Iq_max total
Access level: 3
Can be changed: -
Units group: 6_2
Min
- [Arms]
Description:
Displays the maximum torque/force generating current as a result if all current limits.
r1536[0...1]
Current limit maximum torque-generating current / Isq_max
Access level: 4
Can be changed: -
Units group: 6_2
Min
- [Arms]
Description:
Displays the maximum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
Index:
[0] = Limited
[1] = Unlimited
r1537[0...1]
Current limit minimum torque-generating current / Isq_min
Access level: 4
Can be changed: -
Units group: 6_2
Min
- [Arms]
Description:
Displays the minimum limit for the torque-generating current component.
Index 0 indicates the signal limited by the Vdc controller.
1-212
Calculated: p0340 = 1,3,5
Scaling: -
Unit selection: p0505
Max
100000.00 [kW]
Calculated: p0340 = 1,3,5
Scaling: -
Unit selection: p0505
Max
-0.01 [kW]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6640
Factory setting
0.00 [kW]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6640
Factory setting
-0.01 [kW]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 5640, 5722, 6640
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6640, 6710
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6640, 6710
Factory setting
- [Arms]