p1528[0...n]
CI: Torque limit upper scaling / M_max upper scal
CU240D-2_DP
Access level: 4
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source for the scaling of the upper torque limit in p1522.
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1528[0...n]
CI: Torque limit upper scaling / M_max upper scal
CU250D-2_DP_F
Access level: 4
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the scaling of the upper torque limit in p1522.
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1529[0...n]
CI: Torque limit lower scaling / M_max lower scal
CU240D-2_DP
Access level: 4
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source for the scaling of the lower torque limit in p1523.
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1529[0...n]
CI: Torque limit lower scaling / M_max lower scal
CU250D-2_DP_F
Access level: 4
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the scaling of the lower torque limit in p1523.
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Parameters
List of parameters
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6630
Factory setting
1524[0]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6630
Factory setting
2686[0]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6630
Factory setting
1525[0]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 6630
Factory setting
2686[1]
1-211