Parameters
List of parameters
p2511[0...3]
BI: LR measuring probe evaluation edge / MT_eval edge
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the edge evaluation of the measuring probe.
1 signal = falling edge of the measuring probe (p2510) is activated for BI: p2509 = 0/1 edge.
0 signal = rising edge of the measuring probe (p2510) is activated for BI: p2509 = 0/1 edge.
Index:
[0] = Cl-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p2502, p2509, p2510
p2512[0...3]
BI: LR pos. actual value preprocessing activate corr. value (edge) /
ActVal_prepCorrAct
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the function "activate position actual value preprocessing, corrective value (edge)".
0/1 signal: The corrective value available through CI: p2513 is activated.
Index:
[0] = Cl-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p2502, p2513, r2684
p2513[0...3]
CI: LR Position actual value preprocessing corrective value / Act val_prep corr
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the corrective value for position actual value preprocessing.
Index:
[0] = Cl-loop pos ctrl
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency:
Refer to: p2502, p2512, r2521, r2685
Note:
For BI: p2512[0] = 0/1 signal, the position actual value (CO: r2521[0]) is corrected corresponding to the value via CI:
p2513[0]. In so doing, the sign of the corrective value present is taken into account.
1-320
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3615, 4010
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 4010, 4015
Factory setting
[0] 2684.7
[1] 0
[2] 0
[3] 0
Data type: U32 / Integer32
Dyn. index: -
Func. diagram: 4010, 4015
Factory setting
[0] 2685[0]
[1] 0
[2] 0
[3] 0