r3925[0...n]
Identification final display / Ident final_disp
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the commissioning steps that have been carried out.
Bit field:
Bit
Signal name
00
Motor/control parameters calculated (p0340
= 1, p3900 > 0)
02
Motor data identification carried out at
standstill (p1910 = 1)
03
Rotating measurement carried out (p1960 =
1, 2)
15
Motor equivalent circuit diagram parameters
changed
Note:
The individual bits are only set if the appropriate action has been initiated and successfully completed.
When motor rating plate parameters are changed, the final display is reset.
When setting the individual bits, all of the most significant bits are reset.
r3926[0...n]
Voltage generation alternating base voltage amplitude / U_gen altern base
Access level: 4
Can be changed: -
Units group: -
Min
- [V]
Description:
Displays the base voltage for the alternating voltage in the context of motor data identification.
0:
No alternating voltages. The function is de-activated.
<0:
Automatic determination of the base voltage and wobbulation / self-setting based on the converter and the con-
nected motor.
Otherwise:
Base voltage for alternating current generation in volts (wobbulation active).
r3927[0...n]
Motor data identification control word / MotID STW
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Successfully completed component of the last motor data identification carried out.
Bit field:
Bit
Signal name
00
Stator inductance estimate no measure-
ment
02
Rotor time constant estimate no measure-
ment
03
Leakage inductance estimate no measure-
ment
05
Determine Tr and Lsig evaluation in the time
range
06
Activate vibration damping
07
De-activate vibration detection
11
De-activate pulse measurement Lq Ld
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Changed
Calculated: -
Scaling: -
Unit selection: -
Max
- [V]
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameters
List of parameters
Data type: Unsigned32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
-
0 signal
No
No
No
Not changed
Data type: FloatingPoint32
Dyn. index: MDS
Func. diagram: -
Factory setting
- [V]
Data type: Unsigned32
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
FP
-
-
-
-
FP
-
-
-
-
-
-
-