Parameters
BICO parameters (connectors/binectors)
p1570[0...n]
r1593[0...1]
r1597
r1598
r1718
r1723
r1732[0...1]
r1733[0...1]
r1770
r1771
r1801[0...1]
r1809
r2050[0...11]
r2060[0...10]
r2089[0...4]
r2120
r2121
r2131
r2132
r2169
p2201[0...n]
p2202[0...n]
p2203[0...n]
p2204[0...n]
p2205[0...n]
p2206[0...n]
p2207[0...n]
p2208[0...n]
p2209[0...n]
p2210[0...n]
p2211[0...n]
p2212[0...n]
p2213[0...n]
p2214[0...n]
p2215[0...n]
r2224
r2245
r2250
r2260
r2262
r2266
r2272
r2273
p2291
p2292
r2294
p2295
r2344
r2520[0...2]
r2521[0...3]
r2522[0...3]
r2523[0...3]
r2524
1-562
CO: Flux setpoint / Flex setp
CO: Field weakening controller / flux controller output / Field/Fl_ctrl outp
CO: Field weakening controller output / Field_ctrl outp
CO: Total flux setpoint / Flux setp total
CO: Isq controller output / Isq_ctrl outp
CO: Isd controller output / Isd_ctrl outp
CO: Direct-axis voltage setpoint / Direct U set
CO: Quadrature-axis voltage setpoint / Quad U set
CO: Motor model speed adaptation proportional component / MotMod n_adapt Kp
CO: Motor model speed adaptation I comp. / MotMod n_adapt Tn
CO: Pulse frequency / Pulse frequency
CO: Modulator mode actual / Modulator mode act
CO: PROFIBUS PZD receive word / PZD recv word
CO: PROFIdrive PZD receive double word / PZD recv DW
CO: Send binector-connector converter status word / Bin/con ZSW send
CO: Sum of fault and alarm buffer changes / Sum buffer changed
CO: Counter alarm buffer changes / Alrm buff changed
CO: Actual fault code / Actual fault code
CO: Actual alarm code / Actual alarm code
CO: Actual speed smoothed signals / n_act smth message
CO: Technology controller fixed value 1 / Tec_ctrl fix val1
CO: Technology controller fixed value 2 / Tec_ctr fix val 2
CO: Technology controller fixed value 3 / Tec_ctr fix val 3
CO: Technology controller fixed value 4 / Tec_ctr fix val 4
CO: Technology controller fixed value 5 / Tec_ctr fix val 5
CO: Technology controller fixed value 6 / Tec_ctr fix val 6
CO: Technology controller fixed value 7 / Tec_ctr fix val 7
CO: Technology controller fixed value 8 / Tec_ctr fix val 8
CO: Technology controller fixed value 9 / Tec_ctr fix val 9
CO: Technology controller fixed value 10 / Tec_ctr fix val 10
CO: Technology controller fixed value 11 / Tec_ctr fix val 11
CO: Technology controller fixed value 12 / Tec_ctr fix val 12
CO: Technology controller fixed value 13 / Tec_ctr fix val 13
CO: Technology controller fixed value 14 / Tec_ctr fix val 14
CO: Technology controller fixed value 15 / Tec_ctr fix val 15
CO: Technology controller fixed value effective / Tec_ctr FixVal eff
CO: Technology controller mot. potentiometer setpoint before RFG / Tec_ctr mop befRFG
CO: Technology controller motorized potentiometer setpoint after RFG / Tec_ctr mop aftRFG
CO: Technology controller setpoint after ramp-function generator / Tec_ctr set aftRFG
CO: Technology controller setpoint after filter / Tec_ctr set aftFlt
CO: Technology controller actual value after filter / Tec_ctr act aftFlt
CO: Technology controller actual value scaled / Tech_ctrl act scal
CO: Technology controller error / Tec_ctrl error
CO: Technology controller maximum limiting / Tec_ctrl max_lim
CO: Technology controller minimum limiting / Tec_ctrl min_lim
CO: Technology controller output signal / Tec_ctrl outp_sig
CO: Technology controller output scaling / Tec_ctrl outp scal
CO: Technology controller last speed setpoint (smoothed) / Tec_ctrl n_setp_sm
CO: LR Position actual value preprocessing encoder control word / ActVal_prep STW
CO: LR position actual value / s_act
CO: LR velocity actual value / v_act
CO: LR measured value / Measured value
CO: LR LU/revolution / LU/revolution
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013