Download Print this page

Siemens SINAMICS G120D List Manual page 98

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
r0587
CO: Measuring probe measuring time measured / MT t_meas measured
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the time between the last two BERO pulses.
The measuring time is specified as 32-bit value with a resolution of 1/48 µs.
If a new pulse is not received before the maximum measured time in p0583 expires, then r0587 is set to the maxi-
mum measuring time.
Dependency:
Refer to: p0580
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
r0588
CO: Measuring probe pulse counter / MT pulse counter
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the number of measuring pulses that have occurred (been received) up until now.
Dependency:
Refer to: p0580
Note:
After reaching 4294967295 (2^32 - 1), the counter starts again at 0.
r0589
Measuring probe delay time / MT t_delay
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the time since the last measuring pulse was detected.
The delay time is specified as 32-bit value with a resolution of 1/48 µs.
When a measuring pulse occurs (is received) the delay time is reset and is limited to the maximum measuring time
in p0583.
Dependency:
Refer to: p0580
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
p0595
Technological unit selection / Tech unit select
CU240D-2_DP
Access level: 1
CU240D-2_DP_F
Can be changed: C(5)
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
1
Description:
Selects the units for the parameters of the technology controller.
For p0595 = 1, 2, the reference quantity set in p0596 is not active.
Value:
1:
2:
3:
4:
5:
6:
7:
1-98
%
1 referred no dimensions
bar
°C
Pa
ltr/s
m³/s
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
46
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
1

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all