Signal targets for POS_STW2 (positioning mode)
Signal
Meaning
POS_STW2.0
1 = Activate Tracking mode
POS_STW2.1
1 = Set home position
POS_STW2.2
1 = Reference cam active
POS_STW2.3
Reserved
POS_STW2.4
Reserved
1 = Jogging, incremental active
POS_STW2.5
0 = Jogging, velocity active
POS_STW2.6
Reserved
POS_STW2.7
Reserved
1 = Referencing type selection for flying referencing
POS_STW2.8
0 = Referencing type selection for search for reference
1 = Start the search for reference in the negative direction
POS_STW2.9
0 = Start the search for reference in the positive direction.
1 = Measuring probe 2 is activated
POS_STW2.10
0 = Measuring probe 1 is activated
1 = Falling edge of the measuring probe
POS_STW2.11
0 = Rising edge of the measuring probe
POS_STW2.12
Reserved
POS_STW2.13
Reserved
POS_STW2.14
1 = Software limit switch activation
POS_STW2.15
1 = STOP cam active
<1>
Used in telegram 111.
1
2
PROFIdrive (PROFIBUS/PROFINET)
POS_STW2 Positioning control word 2 interconnection
3
4
Interconnection
[Function diagram]
[Function diagram]
parameters
internal control word
p2655[0] = r2092.0
-
p2596 = r2092.1
-
p2612 = r2092.2
-
-
-
-
-
p2591 = r2092.5
-
-
-
-
-
p2597 = r2092.8
-
p2604 = r2092.9
-
p2510[0] = r2092.10
-
p2511[0] = r2092.11
-
-
-
-
-
p2582 = r2092.14
-
p2568 = r2092.15
-