Download Print this page

Siemens SINAMICS G120D List Manual page 668

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Srch for ref dir
1 = Negative
p2604
0 = Positive
(0)
<1>
Ref_cam pres
0 ... 1
p2607 (1)
Ref_pt coord val
-2147482648 ... 2147482647 [LU]
Rev minus
p2613
<4>
(1)
Rev plus
p2614
<4>
(1)
Ref start
p2595
<2>
(0)
[3614.1]
1 ... 40000000 [1000 LU/min]
Set ref_pt
p2596
<5>
(0)
1 ... 40000000 [1000 LU/min]
Ref_typ select
p2597
<2>
(0)
[3614.1]
1 ... 40000000 [1000 LU/min]
Ref_cam
p2612
(0)
Ref act fdbk
p2659
(2526.1)
[4010.8]
MeasVal valid fdbk
p2661
Feedback
(2526.2)
signals
[3614.2]
[4010.8]
Meas val ref
p2660
[3614.2]
(2523[0])
[4010.8]
<1>
If no reference cam exists, the axis directly moves to the zero mark (in the defined start direction). Without a reference cam, the tolerance bandwidth is not evaluated.
<2>
When "flying referencing" is selected (passive referencing, p2597 = 1 signal), this function diagram is of no significance => refer to [3614].
<3>
The connector outputs are only supplied with values from here if the “referencing“ mode is active.
<4>
The reversing cams are low active. When a cam is actuated, motion (reference cam search) is continued in the opposite direction.
<5>
Reference point setting is only effective in the initial state [3625].
1
2
Basic positioner (EPOS)
Referencing/reference point approach mode (p2597 = 0 signal)
Ref_pt offset
-2147482648 ... 2147482647 [LU]
Approach direction
p2600 (0)
A
Ref_pt coord S_src
p2598
[3614.2]
p2599
(2599[0])
p2599 (0)
Reversing cam
|v|
v_appr ref_cam
p2605 (5000)
v_appr ref_pt
p2611 (300)
III
v_appr ref_ZM
p2608 (300)
Zero marks (ZM)
Zero mark evaluation
<1>
activated
3
4
B
Reversing cam
Position
Velocity
v_set act [1000 LU/min]
r2672
I
100 %
a_over act [%]
r2673
100 %
-a_over act [%]
r2674
II
s
Tol_band to ZM
<1>
0 ... 2147482647 [LU]
p2610 (2147482647)
Max s ref_cam ZM
0 ... 2147482647 [LU]
p2609 (20000)
Ref_cam max s
0 ... 2147482647 [LU]
p2606 (2147482647)
5
fp_3612_97_55.vsd
12.12.2012
POS_ZSW2
r2684
r2684
.11
[3646.3]
POS_ZSW2
r2684
[3646.1]
r2684
.0
Clearance cam/ZM [LU]
r2680
<3>
<3>
Motion variables in “referencing/
reference point approach“ mode
<3>
F07458
"Reference cam not found"
F07459
<1>
"No zero mark"
F07460
"End of reference cam not found"
6
7
Function diagram
G120D CU250D-2
V4.6
[3630.1]
8
- 3612 -

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all