Download Print this page

Siemens SINAMICS G120D List Manual page 438

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
[6] = PZD 7
[7] = PZD 8
Dependency:
Refer to: r9769
Note:
The PROFIsafe trailer at the end of the telegram is also displayed (2 words).
r9769[0...7]
SI PROFIsafe send status words (processor 1) / SI Ps PZD send P1
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the PROFIsafe telegram to be sent on processor 1.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
Dependency:
Refer to: r9768
Note:
The PROFIsafe trailer at the end of the telegram is also displayed (2 words).
r9770[0...3]
SI version drive-integrated safety function (processor 1) / SI version Drv P1
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the Safety Integrated version for the drive-integrated safety functions on processor 1.
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
[3] = Safety Version (hotfix)
Note:
Example:
r9770[0] = 2, r9770[1] = 60, r9770[2] = 1, r9770[3] = 0 --> Safety version V02.60.01.00
r9771
SI common functions (processor 1) / SI general fct P1
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
-
Description:
Displays the supported Safety Integrated monitoring functions.
Processor 1 determines this display.
Bit field:
Bit
Signal name
00
STO supported via terminals
02
Extended Functions supported (p9501 > 0)
04
Extended Functions PROFIsafe supported
05
Extended Functions integrated in drive sup-
ported (p9601.2 = 1)
06
Basic Functions PROFIsafe supported
1-438
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 2802
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2804
Factory setting
-
0 signal
No
No
No
No
No
FP
2804
2804
-
-
-

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all