Parameters
List of parameters
p1582[0...n]
Flux setpoint smoothing time / Flux setp T_smth
Access level: 3
Can be changed: U, T
Units group: -
Min
4 [ms]
Description:
Sets the smoothing time for the flux setpoint.
r1583
Flux setpoint smoothed / Flux setp smooth
Access level: 4
Can be changed: -
Units group: -
Min
- [%]
Description:
Displays the smoothed flux setpoint.
The value is referred to the rated motor flux.
p1584[0...n]
Field weakening operation flux setpoint smoothing time / Field weak T_smth
Access level: 4
Can be changed: U, T
Units group: -
Min
0 [ms]
Description:
Sets the smoothing time for the flux setpoint in the field-weakening range
Note:
Only the flux setpoint rise is smoothed
r1589
Field-weakening current pre-control value / I_FieldWeak prectr
Access level: 4
Can be changed: -
Units group: 6_2
Min
- [Arms]
Description:
Displays the pre-control value for the field weakening current.
r1593[0...1]
CO: Field weakening controller / flux controller output / Field/Fl_ctrl outp
Access level: 4
Can be changed: -
Units group: 6_2
Min
- [Arms]
Description:
Display and connector output for the output of the field weakening controller (synchronous motor).
Index:
[0] = PI output
[1] = I output
1-216
Calculated: p0340 = 1,3
Scaling: -
Unit selection: -
Max
5000 [ms]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
- [%]
Calculated: p0340 = 1,3
Scaling: -
Unit selection: -
Max
20000 [ms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
Calculated: -
Scaling: p2002
Unit selection: p0505
Max
- [Arms]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6722, 6724
Factory setting
15 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6722, 6723, 6724
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6722
Factory setting
0 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6724
Factory setting
- [Arms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6724
Factory setting
- [Arms]