Parameters
List of parameters
p2552
BI: LR signal travel to fixed stop active / Signal TfS act
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the signal "travel to fixed stop active".
BI: p2552 = 1 signal:
The activity associated with travel to fixed stop is signaled and the detection of the fixed stop is started via the max-
imum following error (p2634).
Dependency:
Refer to: r2683
p2553
BI: LR signal fixed stop reached / Signal fixed stop
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the signal "fixed stop reached".
BI: p2553 = 1 signal:
When the fixed stop is reached, this is signaled and the fixed stop monitoring window is activated.
Dependency:
Refer to: r2683
p2554
BI: LR signal traversing command active / Sig trav_cmnd act
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the signal "traversing command active".
BI: p2554 = 1 signal:
It is signaled that positioning is active and therefore the positioning monitoring is not activated with the signal "set-
point present" (p2551).
Dependency:
Refer to: p2551, r2684
p2555
CI: LR LU/revolution LU/mm / LU/rev LU/mm
CU250D-2_DP_F
Access level: 3
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency:
Refer to: p0404, r2524
Note:
The signal value is used to convert the length unit to the speed or velocity setpoint.
1-332
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 4025
Factory setting
2683.14
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 4025
Factory setting
2683.12
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 4020
Factory setting
2684.15
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 4015
Factory setting
2524[0]