Parameters
List of parameters
Re bit 04:
The threshold value is set in r1119 and the hysteresis in p2150.
Re bit 05:
The threshold value is set in p1266 and the delay time in p1228.
Re bit 06:
The hysteresis is set in p2162.
Re bit 07:
The threshold value is set in p2163 and the hysteresis is set in p2164.
Re bit 08:
The threshold value is set in p2170 and the delay time in p2171.
Re bit 09, 10:
The threshold value is set in p2172 and the delay time in p2173.
Re bit 11:
The threshold value is set in p2179 and the delay time in p2180.
Re bit 12:
The threshold value is set in p2182, the hysteresis in p2162, and the delay time (for canceling the signal) in p2152.
Re bit 13:
Only for internal Siemens use.
r2198.0...13
CO/BO: Status word monitoring 2 / ZSW monitor 2
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the second status word for monitoring functions.
Bit field:
Bit
Signal name
00
|n_act| <= speed threshold value 5
01
|n_act| > speed threshold value 5
02
|n_act| <= speed threshold value 6
03
|n_act| > speed threshold value 6
04
|n_set| < p2161
05
n_set > 0
06
Motor blocked
07
Motor stalled
08
|I_act| < I_threshold value p2170
09
|M_act| > torque threshold value 1 and
n_set reached
10
|M_set| < torque threshold value 1
11
Load monitoring signals an alarm
12
Load monitoring signals a fault condition
13
|M_act| > torque threshold value 1
Note:
Re bit 10:
The torque threshold value 1 is set in p2174.
Re bit 12:
This bit is reset after the fault cause disappears, even if the fault itself is still present.
r2199.0...11
CO/BO: Status word monitoring 3 / ZSW monitor 3
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the third status word for monitoring functions.
1-296
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: 1530, 2536
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Data type: Unsigned16
Dyn. index: -
Func. diagram: 1530, 2537
Factory setting
-
FP
8021
8021
8021
8021
8011
8011
8012
8012
8020
8021
8012
8013
8013
8021

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all