p1071[0...n]
CI: Main setpoint scaling / Main setp scal
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for scaling the main setpoint.
r1073
CO: Main setpoint effective / Main setpoint eff
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the effective main setpoint.
The value shown is the main setpoint after scaling.
p1075[0...n]
CI: Supplementary setpoint / Suppl setp
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the supplementary setpoint.
Dependency:
Refer to: p1076, r1077, r1078
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl setp scal
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for scaling the supplementary setpoint.
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
r1078
CO: Total setpoint effective / Total setpoint eff
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the total effective setpoint.
The value indicates the sum of the effective main setpoint and supplementary setpoint.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Parameters
List of parameters
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 1550, 3030
Factory setting
1
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3030
Factory setting
- [rpm]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 1550, 3030
Factory setting
0
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 1550, 3030
Factory setting
1
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3030
Factory setting
- [rpm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3030
Factory setting
- [rpm]
1-157

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all