OFF2 S_src 2
p0845 [C]
(1)
OFF3 S_src 2
p0849 [C]
(1)
OFF1
OFF2
1
OFF3
Bit 9 = 1 --> Ready to exchange process data
Enable internal
missing or
fault with
this reaction
<1>
The drive is ready to accept data.
1
2
Internal control/status words
Status word, sequence control
Bit No.
From the control unit
0
From the control unit
1
From the control unit
2
From the control unit
3
From the control unit
4
From the control unit
5
6
From the control unit
&
7
From the control unit
8
9
10
From the control unit
11
12
From the brake control [2701.8]
From the brake control [2701.8]
13
14
15
3
4
PROFIdrive-Bit
Status word sequence control (r0899)
1 = Ready for switching on
1 = Ready for operation (DC link loaded, pulses inhibited)
1 = Operation enabled (drive follows n_set)
1 = Jog active
1 = No coast down active (OFF2 inactive)
1 = No fast stop active (OFF3 inactive)
1 = Switching on inhibited active
1 = Drive ready
1 = Controller enable
1 = Control requested
Reserved
1 = Pulses enabled
1 = Open holding brake
1 = Command close holding brake
Reserved
Reserved
5
fp_2503_97_53.vsd
12.12.2012
ZSW seq_ctrl
r0899
r0899
r0899.0
r0899.1
r0899.2
r0899.3
r0899.4
r0899.5
r0899.6
r0899.7
r0899.8
<1>
r0899.9
r0899.11
r0899.12
r0899.13
6