p0809[0...2]
Copy Command Data Set CDS / Copy CDS
Access level: 2
Can be changed: T
Units group: -
Min
0
Description:
Copies one Command Data Set (CDS) into another.
Index:
[0] = Source Command Data Set
[1] = Target Command Data Set
[2] = Start copying procedure
Dependency:
Refer to: r3996
Notice:
When the command data sets are copied, short-term communication interruptions may occur.
Note:
Procedure:
1. In Index 0, enter which command data set should be copied.
2. In Index 1, enter the command data set that is to be copied into.
3. Start copying: Set index 2 from 0 to 1.
p0809[2] is automatically set to 0 when copying is completed.
p0810
BI: Command data set selection CDS bit 0 / CDS select bit 0
CU240D-2_DP
Access level: 2
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source to select the Command Data Set bit 0 (CDS bit 0).
Dependency:
Refer to: r0050, p0811, r0836
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The Command Data Set selected using the binector inputs is displayed in r0836.
The currently effective command data set is displayed in r0050.
A Command Data Set can be copied using p0809.
p0810
BI: Command data set selection CDS bit 0 / CDS select bit 0
CU250D-2_DP_F
Access level: 2
CU250D-2_PN_F
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source to select the Command Data Set bit 0 (CDS bit 0).
Dependency:
Refer to: r0050, p0811, r0836
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
The Command Data Set selected using the binector inputs is displayed in r0836.
The currently effective command data set is displayed in r0050.
A Command Data Set can be copied using p0809.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
3
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: Unsigned8
Dyn. index: -
Func. diagram: 8560
Factory setting
0
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 8560
Factory setting
722.3
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 8560
Factory setting
0