p1594[0...n]
Field-weakening controller P gain / Field_ctrl Kp
Access level: 4
Can be changed: U, T
Units group: -
Min
0.00
Description:
Sets the P gain of the field-weakening controller.
p1596[0...n]
Field weakening controller integral-action time / Field_ctrl Tn
Access level: 3
Can be changed: U, T
Units group: -
Min
10 [ms]
Description:
Sets the integral-action time of the field-weakening controller.
r1597
CO: Field weakening controller output / Field_ctrl outp
Access level: 4
Can be changed: -
Units group: -
Min
- [%]
Description:
Displays the output of the field weakening controller.
The value is referred to the rated motor flux.
r1598
CO: Total flux setpoint / Flux setp total
Access level: 3
Can be changed: -
Units group: -
Min
- [%]
Description:
Displays the effective flux setpoint.
The value is referred to the rated motor flux.
p1610[0...n]
Torque setpoint static (SLVC) / M_set static
Access level: 2
Can be changed: U, T
Units group: -
Min
-200.0 [%]
Description:
Sets the static torque setpoint for sensorless vector control (SLVC).
This parameter is entered as a percentage referred to the rated motor torque (r0333).
For sensorless vector control, when the motor model is shut down, an absolute current is impressed. p1610 repre-
sents the maximum load that occurs at a constant setpoint speed.
Notice:
p1610 should always be set to at least 10 % higher than the maximum steady-state load that can occur.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
1000.00
Calculated: p0340 = 1,3,4
Scaling: -
Unit selection: -
Max
10000 [ms]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
- [%]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max
200.0 [%]
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6724
Factory setting
0.00
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 6723, 6724
Factory setting
300 [ms]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6723
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 6714, 6723, 6724,
6725, 6726, 8018
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 1710, 6721, 6722,
6726
Factory setting
50.0 [%]
1-217