r2667
CO: EPOS backlash compensation value / Backlash value
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: -
Units group: -
Min
- [LU]
Description:
Displays the actual effective value for backlash compensation.
Dependency:
Refer to: p2516
Note:
As standard, the following BICO interconnection is established: CI: p2516 = r2667
r2669
CO: EPOS actual operating mode / Op mode act
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: -
Units group: -
Min
-
Description:
Displays the actual active operating mode.
Value = 00 hex -> no operating mode active
Value = 01 hex -> jogging active
Value = 02 hex -> search for reference active
Value = 04 hex -> traversing blocks active
Value = 08 hex -> Positioning for direct setpoint input/MDI active
Value = 10 hex -> Setting-up for direct setpoint input/MDI active
Value = 20 hex -> flying referencing active
Dependency:
Refer to: p2589, p2590, p2595, p2631, p2647, p2653
r2670.0...15
CO/BO: EPOS status word active traversing block / ZSW act trav_block
CU250D-2_DP_F
Access level: 1
CU250D-2_PN_F
Can be changed: -
Units group: -
Min
-
Description:
Displays the status word for the active traversing block.
r2670.0: Active traversing block, bit 0
...
r2670.5: Active traversing block, bit 5
r2670.15: MDI active
Bit field:
Bit
Signal name
00
Active traversing block bit 0
01
Active traversing block bit 1
02
Active traversing block bit 2
03
Active traversing block bit 3
15
MDI active
Dependency:
Refer to: p2631, p2647
Note:
Re bit 00 ... 05:
Displays the active traversing block in the traversing blocks operating mode.
Re bit 15:
For a 1 signal, the operating mode - direct setpoint input/MDI - is active
1-362
Calculated: -
Scaling: -
Unit selection: -
Max
- [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Active
Active
Active
Active
Active
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Integer32
Dyn. index: -
Func. diagram: 3635
Factory setting
- [LU]
Data type: Integer32
Dyn. index: -
Func. diagram: 3625, 3630
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3615, 3625, 3650
Factory setting
-
0 signal
Not active
Not active
Not active
Not active
Not active
FP
-
-
-
-
-

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all