PROFIdrive-Bit
<1>
<5>
Enc Gn_STW S_src
p0480 [n-1]
(0)
Control word for encoder n (n = 1 or 2)
Bit
Selects the function to be activated (with bit value = 1)
Function
Function for bit 7 = 0
no.
(search for reference mark)
0
1
Reference mark
1
2
Reference mark
2
3
Reference mark
3
4
Reference mark
Start/stop/read selected function
4
0
1
0
1
5
0
0
1
1
6
0
0
0
0
Mode of the function to be activated
7
1 = flying measurement
0 = Search for reference mark (zero mark or BERO)
8...12
Reserved
1 = Request cyclic transfer of the absolute position value in
13
Gn_XIST2
(e.g. EQN absolute track; acknowledgment in Gn_ZSW bit 13)
1 = Request parking encoder (handshake with Gn_ZSW bit 14)
14
= acknowledge encoder fault (located in Gn_ZSW, bit 15;
15
Handshake with Gn_ZSW bit 11)
<3>
1
2
Encoder evaluation
Encoder interface, receive signals, encoders 1 ... 2
Geb Gn_STW
r0487[n-1]
Function for bit 7 = 1
(flying measurement)
1
Measuring probe
1
2
Measuring probe
2
3
Measuring probe
3
4
Measuring probe
4
Bits 0...13 control what is transferred in
Gn_XIST 2.
There are 3 alternatives:
- Bit 7 = 0: Position actual value at the reference
mark <2>
- Bit 7 = 1: Position actual value when the
measuring probe edge is received <2>
- Bit 13 = 1:Cyclic absolute position value from
absolute encoder
Interrupt function
id controller
Activate selected function
No function
<4>
3
4
<1>
To the position sensing, encoder n
[4704.3]
<1>
Index [n-1] --> encoder n
Index [0] --> encoder 1
Index [1] --> encoder 2
<2>
Actual position values are read out from Gn.XIST2 using a handshake
procedure. e.g.: Read position value(s) at reference mark(s)
1. Set r0487.[0-3] according to the function to be activated.
2. Set r0487.4 (activate function)
3. Reset all bits from r0487.[0-4] to 0.
4. r0481[0-3] must be active depending on the activated function.
5. Overtravel zero mark(s) until all bits in r0481.[0-3] are reset to 0.
6. Select r0487.[0-3] individually and activate with r0487.5 until r0481.[4-7]
is equal
to 1 and read out the position values in r0483.
7. Reset all bits, starting with r0487.5 followed by r0487.[0-3].
Select function 1 [Bit 3...0]
("search for reference mark 1")
Start function [Bit 6...4]
Function active [Gn_ZSW Bit 0]
Actual value save at the
reference mark
Read generated value [Bit 6...4]
Value from function 1 available
[Gn_ZSW Bit 4]
Position actual value at reference
mark 1 in Gn_XIST2
Further reference marks can be read out according to PROFIdrive profile.
<3>
The bits are processed with the following priority sequence (highest priority
--> lowest priority bit): Bit 14 --> Bit 15 --> Bit 4-7 --> Bit 12 --> Bit 13.
<4>
The checkback signal is provided in Gn_ZSW bit 14, but the encoder is not
actually parked.
<5>
If the "position module" function module is activated, the
interconnection is established via r2520[0]...[1] from [4010.8].
If a standard telegram (PROFIdrive) is selected, the interconnection is
performed according to the specifications of the standard telegrams [2420].