r0198[0...1]
BIOS/EEPROM data version / BIOS/EEPROM vers
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the BIOS and EEPROM data version.
r0198[0]: BIOS version
r0198[1]: EEPROM data version
Dependency:
Refer to: r0018, r0197
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
p0199[0...24]
Drive object name / DO name
Access level: 4
Can be changed: C
Units group: -
Min
0
Description:
Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configura-
tion assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
Note:
The parameter is not influenced by setting the factory setting.
r0200[0...n]
Power unit code number actual / PU code no. act
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the unique code number of the power unit.
Note:
r0200 = 0: No power unit data found
p0201[0...n]
Power unit code number / PU code no
Access level: 3
Can be changed: C(2)
Units group: -
Min
0
Description:
Sets the actual code number from r0200 to acknowledge the power unit being used.
When commissioned for the first time, the code number is automatically transferred from r0200 into p0201.
Note:
The parameter is used to identify when the drive is being commissioned for the first time.
The power unit commissioning can only be exited (p0201 = r0200), if the actual and acknowledged code numbers
are identical (p0010 = 2).
When the code number is changed, the connection voltage (p0210) is checked and, if necessary, adjusted.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Parameters
List of parameters
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: PDS
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: PDS
Func. diagram: -
Factory setting
0
1-47