Parameters
List of parameters
Dependency:
Refer to: r5613
Note:
Pe: PROFIenergy profiles
r7758[0...19]
KHP Control Unit serial number / KHP CU ser_no
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the actual serial number of the Control Unit.
The individual characters of the serial number are displayed in the ASCII code in the indices.
For the commissioning software, the ASCII characters are displayed uncoded.
Dependency:
Refer to: p7765, p7766, p7767, p7768
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Note:
KHP: Know-How Protection
p7759[0...19]
KHP Control Unit reference serial number / KHP CU ref ser_no
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the reference serial number for the Control Unit.
Using this parameter, if a Control Unit and/or a memory card is replaced at the end customer, the OEM can again
adapt the project to the modified hardware.
Dependency:
Refer to: p7765, p7766, p7767, p7768
Note:
KHP: Know-How Protection
- The OEM may only change this parameter for the use case "Sending encrypted SINAMICS data".
- SINAMICS only evaluates this parameter when powering up from the encrypted "Load into file system..." output or
when powering up from the encrypted PS files. The evaluation is only made when know-how protection and mem-
ory card copy protection have been activated.
r7760
Write protection/know-how protection status / Wr_prot/KHP stat
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the status for the write protection and know-how protection.
Bit field:
Bit
Signal name
00
Write protection active
01
Know-how protection active
02
Know-how protection temporarily withdrawn Yes
03
Know-how protection cannot be deactivated Yes
04
Memory card copy protection active
Dependency:
Refer to: p7761, p7765, p7766, p7767, p7768
Note:
KHP: Know-How Protection
Re bit 00:
Write protection can be activated/deactivated via p7761 on the Control Unit.
Re bit 01:
The know-how protection can be activated by entering a password (p7766 ... p7768).
1-388
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
No
FP
-
-
-
-
-